Testing chamber for Complexe tests Clima CORR CC 1000-FL (80˚C), top loading

The 1000 L climatic chamber allows complex tests of corrosion resistance, condensation and humidity tests, salinity tests up to + 80° C and relative humidity up to 98%. The network link option Internet and storage capacity of up to 50 test programs.
It meets most of the ISO and ASTM international standards eg DIN EN ISO 11997-1: 2006 Cycle B (formerly VDA 621-415), VW PV 1210 (external climate module required), Nissan CCT1, Renault ECC1 ), Volvo STD 423_0014, GM GMW 3172, IEC-60068-2-52 KB

Manufacturer:
VLM Germany
Price:
on request
Model:
Clima CORR CC 1000-FL(80˚C)




Description
  • Operating temperature range from ambient up to +80°C
  • Advanced steel design of the chamber allows for fast temperature and humidity transient times making this test chamber perfectly suitable for accelerated corrosion tests
  • The patented VLM technology allows the best possible reproducibility of the climate conditions being created in the test chamber regardless the environmental conditions and geographical location
  • It has in total 9 different sensors are monitoring all relevant test parameters being temperature, humidity, air flow during the drying phase and the purity of the demineralized water
  • The test chamber made of steel is more robust and less susceptible for damages compared to the competitive products made of glass reinforced plastic
  • Lower cost of ownership compared to the competitive products where the test chamber is made of glass reinforced plastic (shorter test periods, better energy efficiency, easier for service and maintenance, longer life cycle, more resistive to mechanical damages)
  • Ethernet interface for connecting to local intranet
  • Memory storage with the capacity to hold of 50 test programs,  most common corrosion tests already preconfigured in the factory
  • The Beckhoff PLC controls remotely the external climate module for the tests which require such module (typically PV 1210 and Renault ECC1)
  • Alarm table and history log

International Standard tests that can be performed with the ClimaCorr, deppending on the selected model and specific acccesories that may be required for each type of test:

Relevant Test Standards:

– DIN EN ISO 11997-1:2006 Cycle B (previously VDA 621-415), VW PV 1210 (external climate module required), Nissan CCT1, Renault ECC1 (external climate module required), Volvo STD 423_0014, GM GMW 3172, IEC-60068-2-52 KB

Cyclic Climate Tests:

– DIN EN ISO 11997-1:2006 Cycle B (previously VDA 621-415), VW PV 1210 (climate module required), Nissan CCT 1, Renault ECC1 (climate module required), Volvo STD 423_0014 (option), GM GMW 3172 (option), IEC-60068-2-52 KB

Salt Spray Test:

– DIN EN ISO 9227, DIN 50942, DIN 53167, ASTM B 117-73, ASTM B 287-74, ASTM B 368-68, ISO 7253 ISO 3678, BS 1224, BS 2011, BS3900 F4, BS 3900 F12, BS 5466 Part I, BS 5466 Parts 2 + 3, NFX 41002, AS 21331 Section 3.1, SIS 1841190, JIS Z 2371

Condensation water test:

– ISO 6270-2, BS 3900F2, BS 3900 F15, ASTM D2242

Specifications

ClimaCORR CC 1000-FL (80˚C), code V.745.672.430

Testing chamber for Complexe tests Clima CORR 80˚C CC 1000-FL, front loading

Capacity

ca. 1000 L

Inner test chamber dimensions (WxDxH1/H2)

ca. 1400 x 800 x 800 /1020 mm

Outer dimensions of the casing (WxDxH)

ca. 2160 x 1000 x 2070 mm

Required power supply

400 V, 50/60 Hz, 7 KW, CEE plug 16 A, 5P

Materials used

test chamber is made of stainless steel and coated with ECTFE (Halar®), additional side walls made of special Polyethylene with milled openings for supporting rods

Heating

Flat Micanite heaters under the bottom of the chamber and behind the rear wall for fast and uniform heat transfer

Sensors

– corrosion resistant and highly sensitive temperature sensors above the floor, at the side wall and under the roof
– a mobile temperature sensor in the sample zone
– humidity sensor

Cooling

Wall rinsing for rapid cooling of the test chamber and quick alteration of the climate conditions

Regulated humidity

Regulation from ambient up to 95% (including humidity ramp function)

Max operating temperature

+80˚C

Other specification

Purity demineralized water (connection type)

< 5 μS/cm (¾“ outer diameter)

Tap water (connection type)

¾“ outer diameter (demineralized water required)

Compressed Air

6-8 bar (connection nipple size 5)

Accessories
Direct Spraying of the Solution (1000-FL)
code V.850.211.110
Spray test solution (Ford / Volvo) for 1000L test chambers
code V.850.211.112
Additional cable gland (Ø 150 mm) for 1000 L test chambers
code V.850.230.720
Spraying of test solution (GMW 3172) for 1000 L test chambers
code V.850.211.113
Load support for 1000 L test chambers (350 kg)
code VA.745.000.034
Monitoring the pH value of the test solution
code V.850.250.011
Racks PP for SAL/CCT/ClimaCORR® test cabinets 1000 L; Slits: 27; Angle: 20°; Slit width: 3mm; Length :650 mm
code V.851.210.330
Tanks for test solution with SAL filter, 210 L, 2 fixed 2 swivel castors
code V.852.220.210
Container pump 230 V for rapidly dissolving of sodium chloride (for the 210L/ 300L tank)
code V.852.225.111
Air duct for distribution of salt fog in 1000 L and larger chambers where nozzle is on a side of the chamber (test requirement)
code V.852.000.631
Climatic module, climate acc. to, ISO 554 for VW PV 1210
various models: V.850.400.XXX, on request
Compressor, max pressure 8 bar
code V.852.211.111
Unit for filtering compressed air, for test cabinets 400/600/1000 L
code V.852.210.104
Water plant for the demineralization of tap water according to ISO 9227, ASTM B117 (1 cartridge, analogue conductivity meter, leak water detection)
code V.852.250.002
Aplication

-Automotive Industry

-Paint Industry

–Metal Industry

–Aerospace Industry

International Standard tests that can be performed with the ClimaCorr, deppending on the selected model and specific acccesories that may be required for each type of test:

Relevant Test Standards:

DIN EN ISO 11997-1:2006 Cycle B (previously VDA 621-415) ,VW PV 1210 (external climate module required) , Nissan CCT1 ,Renault ECC1 (external climate module required) ,Volvo STD 423_0014 ,GM GMW 3172 ,IEC-60068-2-52 KB

Cyclic Climate Tests: DIN EN ISO 11997-1:2006 Cycle B (previously VDA 621-415),VW PV 1210 (climate module required) ,Nissan CCT 1 ,Renault ECC1 (climate module required) ,Volvo STD 423_0014 (option) ,GM GMW 3172 (option) ,IEC-60068-2-52 KB

Salt Spray Test: DIN EN ISO 9227 ,DIN 50942, DIN 53167, ASTM B 117-73, ASTM B 287-74 ,ASTM B 368-68 , ISO 7253 ISO 3678 ,BS 1224, BS 2011, BS3900 F4 ,BS 3900 F12 ,BS 5466 Part I, BS 5466 Parts 2 + 3 ,NFX 41002, AS 21331 Section 3.1 ,SIS 1841190 ,JIS Z 2371

Condensation water test: ISO 6270-2 ,BS 3900F2, BS 3900 F15 , ASTM D2242

Request